Tube Assembly
Pusher Pin
Plunger Assembly
Spring
Cleaning the Solenoid Valve
1. Unscrew nut on top of solenoid valve coil.
2. Remove solenoid valve coil with cable still attached.
3. Remove solenoid valve tube assembly.
4. Use socket spanner on filter nut to avoid damaging brass nut.
Filter
Nut
5. Use 8mm dia. Drill bit to clean connecting pipe.
Basket must be out our it may get damaged.